• Modular Air Handling Unit(Purification Air Conditioning Units)
  • Modular Air Handling Unit(Purification Air Conditioning Units)

Modular Air Handling Unit(Purification Air Conditioning Units)

It adopts a new type of concave-convex groove snap-in forced sealing frame composite profile structure. The inside and outside of the box are organically combined through polyurethane foaming and composite profiles, eliminating the heat conduction existing in the aluminum profiles. Based on the flat inner wall of the box, the inner corners of the wall break through the traditional design and adopt an inner arc transition, making the unit more conducive to purification. The double-frame structure inside and outside the box further enhances the strength and rigidity of the box. The product has the advantages of complete functions, convenient and flexible selection and combination, novel structural design, etc., and is widely used in various occasions.
  • Modular Air Handling Unit(Purification Air Conditioning Units)

Description

  • Innovative structural design
    Adopts a patented frameless labyrinth structure, completely eliminating cold bridges, effectively preventing heat transfer, and improving energy efficiency. The hidden steel frame structure is suitable for high-purification industries with high pressure and other characteristics, demonstrating the product's professionalism and adaptability. The high-strength, cold-bridge-free, environmentally sealed door enhances the unit's sealing and environmental performance.
  • Sealing and hygiene design
    Glueless sealing structure, the unit adopts inner arc sealing design, with a flat interior, no dust accumulation, easy to clean and maintain. Hygienic water tray design, dual-direction large inclination dry water tray, no water accumulation, no bacterial growth, ensuring the hygienic conditions inside the unit, especially suitable for places with high hygiene requirements.
  • Flexibility and adaptability
    Modular design, the height and width of the unit can be flexibly selected to meet different space and functional requirements. Flexible functional section selection, suitable for various occasions, whether commercial buildings, hospitals, or industrial environments, can provide customized solutions.
Performance and quality assurance
High-density insulation panels provide excellent insulation performance, reducing energy loss. Dual noise reduction design reduces mechanical noise, creating a quiet operating environment. The patented filter installation frame, high strength, high sealing, ensures filtering effect and air quality, reflecting the product's high standards in performance and quality.

  • Medical Air Conditioning Units
Specific Response Strategies and Product Features: The medical air conditioning unit features a patented structural design with broken cold bridges, forced sealing, no sanitary dead corners, and high strength. This design enables the unit to provide a more reliable, energy-efficient, and clean solution for the cleanrooms in the medical purification industry. Advantages of the Heat and Moisture Exchange Components: The unit can choose between a direct evaporative coil and a chilled water coil for cooling and dehumidification. Moreover, the selection of these coils is designed and calculated using professional selection software, ensuring that the selection parameters of the heat exchange coils are consistent with the actual operating parameters. This allows for very precise regulation of temperature and humidity in different medical environments. For example, in some special treatment rooms or pharmaceutical inspection rooms that are sensitive to temperature and humidity, whether it is necessary to quickly dehumidify, effectively cool down, or heat up, the unit can operate stably according to the set requirements.

  • Operating Room Dual Cooling Sources Deep Dehumidification Fresh Air Unit

Aiming at the persistent problem of excessive humidity in operating rooms, Veck uses a new fresh air unit with dual cold sources for deep dehumidification in operating rooms to pre-treat the fresh air and obtain dry fresh air. The fresh air independently bears the outdoor load and the indoor moisture load, while the circulating fan unit only bears the indoor sensible heat load. Through this temperature and humidity separate control system, the problem of excessive humidity in operating rooms and laboratories can be effectively solved. Advantages in the Precision and Efficiency of Humidity Control:This unit can control the indoor humidity within an ideal range with high precision. Compared with some traditional dehumidification solutions, it can respond more quickly and stably to humidity fluctuations, improving the quality of humidity control in the entire medical environment. It ensures that the normal operation of high-precision instruments and equipment is not affected by humidity, extends the service life of the equipment, and at the same time provides a favorable air environment for the treatment and recovery of patients.

  • Dehumidification and Reheating Solutions for Purification Air Conditioning Units

During the dehumidification process of the purification air conditioning unit, reheating is a major energy consumption point, and the four-pipe air-cooled screw (scroll) chiller-heater unit can solve this problem. In the summer cooling season, the unit can provide free hot water. For dehumidification and reheating, the free hot water provided during the refrigeration process of the air source heat pump can be utilized for reheating, which solves the problem of the heat source for dehumidification and reheating of the purification unit. Features of Operational Stability and Reliability:The four-pipe air-cooled screw (scroll) chiller-heater unit can continuously provide hot water, ensuring the stable operation of the purification unit.

  • Air Conditioning Solutions for Outpatient , Medical Technology Department and Inpatient Department Areas

Advantages of DC Brushless Fan Coil Units: Veck's "DC brushless fan coil units" are mainly used in areas such as outpatient departments, medical technology departments, and inpatient departments. Their features include: The fan can be steplessly speed-regulated, which makes the indoor temperature regulation in these areas more comfortable and meets the different requirements of different people for temperature and air volume. Equipped with DC brushless motors, they have low energy consumption, and the energy saving of the system operation can reach more than 80%. In places like hospitals where air conditioners are used for a long time, it can significantly reduce energy costs and the overall operating costs of the hospital. Functional Features of the Purification and Filtration Unit: The "purification and filtration unit" used in the areas of outpatient departments, medical technology departments, and inpatient departments has the characteristics of high efficiency, low resistance, no pollution, no ozone generation, moisture resistance, and high stability. It can ensure compliance with the requirements of the Code for Design of General Hospital Buildings (GB51039-2014), guarantee the indoor air quality, and provide a relatively clean and healthy spatial environment for patients and medical staff.

  • Integrated Medical Precision Air Conditioning Unit for Hospital Reconstruction and Expansion Projects.

Advantages of Product Structure and Utilization of Machine Room Space: For some hospital reconstruction and expansion projects, in cases where there is no independent air conditioning machine room or the installation space of the machine room is small, Veck's integrated medical precision air conditioning unit is an excellent solution. This unit integrates mechanical and electrical components, combining three parts: purification air conditioning equipment, humidification equipment, and intelligent temperature and humidity control equipment into one, achieving integration. With a compact structure, it can achieve a very high utilization rate of equipment space, occupying a small area. There is no need for a dedicated air conditioning machine room. The unit can be directly installed in areas such as the sewage corridor, effectively solving the problem of insufficient space and ensuring the requirements for temperature, humidity, and air quality in the medical environment. Features in Operational Efficiency and Environmental Adaptability: It adopts a DC variable frequency EC fan, which can achieve stepless speed regulation from 0 to 100%. It has the characteristics of high efficiency and low noise. The fan motor is directly connected for transmission and each unit has undergone strict dynamic and static balance tests. Such high operational efficiency and low noise can meet the special environmental requirements of hospitals. It not only avoids noise interference with patients' rest and medical staff's work but also can precisely adjust the air quality, temperature, and humidity in various different medical environments, adapting to the new layout and environmental conditions after the hospital reconstruction and expansion.

  • Solutions for the Cooling Source of Hospital Building Systems

The oil-free centrifugal machine adopts the internationally leading dynamic pressure gas bearing structure. The product applies a number of core technologies such as high-efficiency permanent magnet synchronous motors, two-stage compression, and secondary subcooling. It has many characteristics including oil-free and high-efficiency operation, stability and reliability, cost savings, low noise, and environmental friendliness, and is at an internationally advanced level. At the same time, it is equipped with a reliable industrial-grade microcomputer control system, group control technology, and building communication interfaces, ensuring excellent operability and rich expandability of the unit.

Message Us